HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD

Manufacturer from China
Verified Supplier
6 Years
Home / Products / Flammability Testing Equipment /

CTI 0-600V Tracking Index Horizontal Flammability Tester

Contact Now
HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MsTessa Huang
Contact Now

CTI 0-600V Tracking Index Horizontal Flammability Tester

Ask Latest Price
Video Channel
Brand Name :HeJin
Model Number :LT-3
Certification :calibration certificate(cost additional)
Place of Origin :China
MOQ :1 set
Price :Negotiatable
Payment Terms :L/C, T/T
Supply Ability :10 set per month
Delivery Time :30 days
Packaging Details :Plywood
Electrode material :Platinum 5mm*2mm
Electrode angle :60°
Test voltage range :0-600V
Dripping liquid Height :35±5mm
Electrode pressure :1±0.05 N
Testing voltage :0-600V adjustable
Product name :Flammability Test Chamber
Standard :IEC 60112, IEC 60335
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Flammability Testing Equipment Tracking Index Apparatus CTI 0-600V Voltage

Standard:

The tracking index apparatus is designed and manufactured to perform the test specified in the norm IEC 60112 ("method for determining the comparative and the proof tracking index of solid insulating materials under moist conditions") and many others standards ( IEC 60335, IEC 60065, IEC 60745, IEC 61029 ) to determine compliance with safety requirements related to solid insulating materials under moist conditions.

Feature:

Tracking index tester which is also called as tracking tester is for the determination of the proof and comparative tracking indices of solid insulating materials on pieces taken from parts of equipment and on plaques of material using alternating voltages. By providing comparative tracking index (CTI), proof tracking index (PTI), electrical erosion (as required), the tester can help people to evaluation the safety of electrical apparatus.

Application:

The product is typically used to asses the tracking characteristics of an insulator due to liquid impurities that create conducting paths along the insulator surface. Flammability Testing Equipment

Parameter:

Timing device 9999X0.1S Resolution Drip interval Adjustable
Electrode material Platinum The height of the drip 30-40mm
Electrode specifications 5mm*2mm Drip delay 0.2S (solenoid valve open time)
Electrode spacing 4±0.1mm Drip size 45 - 50 drops / cm3
Electrode pressure 1±0.05 N Delay electric circuit 2 ± 0.1S (at 0.5A)
Electrode angle 60° Test voltage range

0-600V

Accuracy:1.5%

Short circuit voltage drop 8% MAX Electrical parameters 1.5KW/220VAC/50Hz
Short-circuit current 1±0.1A Accuracy: 1% Working volume > 0.5 M³. Flammability Testing Equipment

CTI 0-600V Tracking Index Horizontal Flammability Tester

Inquiry Cart 0