Add to Cart
IEC 60529 Figure 6 IP Test Equipment Jet Nozzle For IPX5 IPX6
Standard:
IEC 60529 Degrees of protection provided by enclosures (IP Code) clause 14.2.5 Test for second characteristic numeral 5 with the 6,3 mm nozzle and clause 14.2.6 Test for second characteristic numeral 6 with the 1 2,5 mm nozzle and figure 6, IEC 60598-1 clause 9.2.6 and 9.2.7.
Test sample:
Electronic components, outdoor lamps, auto parts and etc.
Feature:
The handle and nozzle are made of stainless steel, good anti-rust performance.
The nozzle can be replaced to test for IPX5 or IPX6.
Can match the complete set of waterproof system.
Test conditions:
internal diameter of the nozzle: 6.3 mm(IPX5) and 12.5mm(IPX6);
– delivery rate: 12.5 l/min ± 5 % (IPX5) and 100 l/min ± 5 % (IPX6);
– water pressure: to be adjusted to achieve the specified delivery rate;
– core of the substantial stream: circle of approximately 40 mm(IPX5) and 120mm(IPX6) diameter at 2.5 m distance from nozzle;
– test duration per square metre of enclosure surface area likely to be sprayed: 1 min;
– minimum test duration: 3 min;
– distance from nozzle to enclosure surface: between 2,5 m and 3 m.
Parameter:
Model | HH0804-1 | HH0804-2 |
Item | IPX5 | IPX6 |
The nozzle diameter | Ф6.3mm | Ф12.5mm |
Water flow | 12.5±0.625L/min, Flow meter is adjustable | 100±5 L/min, Flow meter is adjustable |
The distance from jet nozzle to enclosure | 2.5~3m | |
Testing time | Not less than 1min/m²(not less than 3 mins) | |
Pressure gauge | 0~0.25MPa | |
Site requirements | Dedicated IP waterproof test room whose width is more than 3m, With good function of inflow and drainage. Wall installation | |
Water supply | Water flow rate > 12.5L/min±5% clean water without inclusion. It can be achieved by the stainless steel water tank and pressurized equipment | Water flow rate >100L/min±5% clean water without inclusion. It can be achieved by the stainless steel water tank and pressurized equipment |