Add to Cart
Auto Parts Test Equipment Safety Test System For Electrically Vehicle
Standard:
ISO 6469-1 Electrically propelled road vehicles-Safety specifications-Part1: On-board rechargeable energy storage system (REESS)
GB/T 18384.1 Electrically propelled road vehicles-Safety specifications-Part1: On-board rechargeable energy storage system (REESS)
GB/T 18487.1 Electric vehicle conductive charging system-Part 1: General requirements
GB/T 20234.1 Connection set for conductive charging of electric vehicles-Part 1: General requirements
Feature:
1. Multifunctional integration: AC and DC withstand voltage, charging socket insulation, vehicle insulation, insulation resistance monitoring, leakage current, potential equanlization, fast charging function, slow charging function eight in one;
2. High test accuracy: basic accuracy of safety test is 1.5%, and electrical parameter measurement accuracy is 0.5%;
3. Record the VIN number, VSN number and main parts number of the vehicle, and print a test result for each vehicle;
4. Bar code identification, automatic matching, automatic and intelligent testing;
5. Data storage, query screening, information management;
6. Perfect protection: the device is not plugged in and the high voltage detection is not started; unplugging the plug in the detection state will cut off the power supply to the socket;
7. Extendable docking with MES system; Auto Parts Test Equipment
Parameter:
Potential equanlization | ||
Test channel | 10 channels | |
Test method / no-load output voltage | four-wire system, <12V | |
Output current setting range | DC:1.00-5.00A 50/60Hz | |
Output current accuracy | ±(1.5% setting value+0.20A) | |
Ground resistance setting range | Upper limit: 0-600 mΩ; lower limit: 0-600 mΩ; 0=off | |
Zero resistance | 0-200 mΩ | |
Ground resistance measurement range | 0-600 mΩ | |
Ground resistance measurement accuracy | ±(1.5% reading value+3 mΩ) | |
Test time setting range/accuracy | 0.0, 0.1-999.9s; 0.0=continue output; ±(0.1% setting value+0.05s) | |
Charging socket insulation test; Auto Parts Test Equipment | ||
Rated output load/current | 1VA(1000V/1mA), 1mA | |
Output voltage ripple | Resistance load, 1000V/1mA, <5% | |
Output voltage setting range/accuracy | DC:100-1000V Continuous Adjustable, ±(1.5% setting value+3V) | |
Insulation resistance setting range | Upper limit: 0.1-3000 MΩ; 0=off; lower limit: 1-3000 MΩ | |
Resistance compensation | >30 MΩ | |
Insulation resistance measurement range | 0.05-99.99-999.9-3000 MΩ | |
Insulation resistance measurement accuracy | 100-499V:<100 MΩ: ±(5% reading value+0.5MΩ); 100 MΩ-1000 MΩ: ±(10% reading value+5MΩ) | |
500-1000V:<100 MΩ: ±(2% reading value+0.2MΩ); 100 MΩ-1999 MΩ: ±(5% reading value+2MΩ); 2000 MΩ-3000 MΩ: ±(10% reading value+5MΩ); | ||
Delay time setting range | 0.5-999.9s | |
Test time setting range/accuracy | 0.0, 0.1-999.9s; 0.0=continue output; ±(0.1% setting value+0.05s) | |
Vehicle insulation test | ||
Insulation resistance setting range | Upper limit: 0, 0.00-100.00MΩ; 0=off; lower limit: 0.00-100.00 MΩ | |
Insulation resistance measurement range | 0.05-99.99-999.9-3000 MΩ | |
Insulation resistance measurement accuracy | ±(5% reading value +0.03% range) | |
Test time setting range | 4.0-999.9s; 0.0=continue output | |
Test time setting accuracy | ±(0.1% setting value+0.05s) | |
Insulation monitoring test | ||
Test time setting range | 4.0-999.9s; 0.0=continue output | |
Test time setting accuracy | ±(0.1% setting value+0.05s) | |
AC withstand voltage test | ||
Withstand voltage test type | Cold withstand voltage test | |
Rated output load | 200VA (AC: 5000V/40mA) | |
Output voltage adjustment rate | <2%(No load to full load) | |
Output voltage setting range | AC: 100-5000V; 50Hz/60Hz | |
Output voltage accuracy | ±(1.5% setting value+3V) | |
Breakdown current setting range | Upper limit: 0.000-9.999-40.00mA; lower limit: 0.000-9.999-40.00mA 0.000=off | |
Zero current | 0.000-2.000mA | |
Breakdown current measurement range | 0.050-9.999-40mA | |
Breakdown current measurement accuracy | ±(1.5% setting value+0.005mA) | |
Rise time/slow down time | 0.0-999.9s | |
Test time setting range | 0.0, 0.1-999.9s; 0.0=continue output | |
Test time setting accuracy | ±(0.1% setting value+0.05s) | |
DC withstand voltage test | ||
Withstand voltage test type | Cold withstand voltage test | |
Rated output load | 60VA (DC: 6000V/10mA) | |
Output voltage adjustment rate | <2%(No load to full load) | |
Output voltage setting range | DC: 1000-6000V; 50Hz/60Hz | |
Output voltage accuracy | ±(1.5% setting value+3V) | |
Breakdown current setting range | Upper limit: 0.000-9.999-10.00mA; lower limit: 0.000-9.999-10.00mA 0.000=off | |
Zero current | 0.000-2.000mA | |
Breakdown current measurement range | 0.050-9.999-10mA | |
Breakdown current measurement accuracy | ±(1.5% setting value+0.005mA) | |
Rise time/slow down time | 0.0-999.9s | |
Test time setting range | 0.0, 0.1-999.9s; 0.0=continue output | |
Test time setting accuracy | ±(0.1% setting value+0.05s) | |
Leakage current test | ||
Leak type setting | Single phase (static, dynamic) | |
Output voltage ratio | 1.1 times input voltage (output by isolation transformer)/arbitrarily set voltage (output by variable frequency power supply) | |
Output voltage setting range | AC: 0.0-300.0V | |
Output voltage measurement range | AC: 5.0-300.0V | |
Output voltage measurement accuracy | ±(1.5% reading value+3V) | |
Leakage current setting range | Upper limit: 0.000-5.000mA; lower limit: 0.000-5.000mA; 0.000=off | |
Zero current | 0.000-2.000mA | |
Leakage current measurement range | 0.50-9.999-20.00 mA | |
Leakage current measurement accuracy | ±(1.5% reading value+5 words) | |
Test time setting range | 0.0, 0.1-999.9s; 0.0=continue output | |
Test time setting accuracy | ±(0.1% setting value+0.05s) |