HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD

Manufacturer from China
Verified Supplier
6 Years
Home / Products / IEC Test Equipment /

4000cm3 0.55MPa IEC Test Equipment Ageing In Air Oxygen Bomb

Contact Now
HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MsTessa Huang
Contact Now

4000cm3 0.55MPa IEC Test Equipment Ageing In Air Oxygen Bomb

Ask Latest Price
Video Channel
Brand Name :HeJin
Model Number :HJ0606
Certification :Third party calibration certificate/ CE(cost additional)
Place of Origin :China
MOQ :1 Set
Price :Negotiatable
Payment Terms :T/T, L/C
Supply Ability :10 set per month
Delivery Time :30 days
Packaging Details :Plywood
Product name :Oxygen Bomb (air bomb) Ageing Tester HJ0606
Usage :wire and cable, rubber
Material :Stainless steel
Temperature range :0-200℃
Tank volume :4000cm3
Temperature Deviation :±1℃
air test pressure :0.55 MPa ± 0.02 MPa
test gas :Oxygen / air
test time :96h
oxygen test pressure :2.1 MPa ± 0.07 MPa
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

IEC Test Equipment Ageing In An Air Bomb/Oxygen Bomb 0.55MPa Test Pressure

Standard:

IEC 60811-11-2 ‘Common test methods for insulating and sheathing materials of electric and optical cables — Part 1-2: General application — Thermal ageing methods’ clause 8.2 and 8.3 ;

IEC 60335-1 ‘Household and similar electrical appliances – Safety – Part 1: General requirements’ clause 22.32;

Application:

It is suitable for the aging test in the oxygen and compressed air to the wire and cable, rubber (plastic, leather) insulation and sheathing, as well as other polymer materials under the action of a predetermined pressure and temperature. IEC Test Equipment

Standard description:

The bomb shall be filled with air, which shall be free from oil and moisture, to a pressure of 0.55 ± 0.02 MPa. The test pieces shall be kept in the bomb at the temperature and for the time specified for the material in the standard for the type of cable.

The bomb shall be filled with commercial oxygen of not less than 97 % purity to a pressure of 2.1 ± 0.07 MPa. The test pieces shall be kept in the bomb at the temperature and for the time specified for the material in the standard for the type of cable.

Parameter:

Parameters Name Parameter Data
Power AC 220V±10%, 50Hz
Tank volume 4000cm3
Heater power 2.4KW
Maximum Working Pressure 4MP/cm2
Security Burst Pressure 2.7-3.3MP/cm2
Temperature Deviation ±1℃. IEC Test Equipment
Temperature self-control range Room temperature 0-200℃
Temperature control Digital display automatic control
Tank materials Stainless steel

4000cm3  0.55MPa IEC Test Equipment Ageing In Air Oxygen Bomb

Inquiry Cart 0