HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD

Manufacturer from China
Verified Supplier
6 Years
Home / Products / Leak Testing Equipment /

Sniffer Type Helium Leak Testing Equipment For Air Conditioner Heat Exchanger

Contact Now
HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MsTessa Huang
Contact Now

Sniffer Type Helium Leak Testing Equipment For Air Conditioner Heat Exchanger

Ask Latest Price
Video Channel
Brand Name :HeJin
Certification :Third party calibration certificate(cost additional)
Place of Origin :China
MOQ :1 Set
Price :Negotiatable
Payment Terms :T/T, L/C
Supply Ability :3 set per 3 month
Delivery Time :90 days
Packaging Details :Plywood
test sample :Air conditioner heat exchanger
machine type :Sniffer Type
Gross Leak Test :Nitrogen
Gas for Fine Leak Test :Helium
Alarm leak rate :3.34x10-5mbar.L/s
Scanning :Manually sniffing
Pressure for Leak Test :40-50bar
Working Bench Size :1200mmX900mm
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Sniffer Type Helium Leak Testing Equipment For Air Conditioner Heat Exchanger

General Information:

The Systems manufactured by HeJin use Helium as tracing gas for detecting leaks.

This test allows measuring the defined the leak position on the component/test piece. In this case the Test piece to Be Tested is connected to the helium filling joint. Then the Test piece are pressurised with helium. Tracing gas come out from test piece through leaks and is detected and measured by sniffer connected to Helium Mass Spectrometer. Helium Leak Testing Equipment

System Description:

The system proposed has a totally automatic cycle with manual load and unload of the Test pieces.

The Test Cycle can be described in the following way:

  • Manual connect the test piece to the helium filling joint.
  • Pressurization of test pieces with nitrogen.
  • Pressure decay to reveal gross leaks;
  • Pressure discharge and test pieces evacuation;
  • Pressurization of test pieces with helium.
  • Manual leak test with sniffer detector.
  • Helium recovery from test pieces.
  • Manual unload the test piece.

Technical Indicators:

Components to be tested Air conditioner heat exchanger
Gross Leak Test Nitrogen
Tracing Gas for Fine Leak Test Helium
Alarm Leak Rate 3.34x10-5mbar.L/s
Pressure for Leak Test 40-50bar
Scanning Manually sniffing
Evacuate, filling and recovery connector 1 stations, 2 sets of joints per station (only 1/4 thread, customer-supplied joints)
Working Bench Size 1200mmX900mm
Recovery Recovery Rate ≥95% Helium Leak Testing Equipment