HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD

Manufacturer from China
Verified Supplier
6 Years
Home / Products / Flammability Testing Equipment /

IEC 60112 Flammability Testing Equipment Tracking Index Touch Screen Operation

Contact Now
HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MsTessa Huang
Contact Now

IEC 60112 Flammability Testing Equipment Tracking Index Touch Screen Operation

Ask Latest Price
Video Channel
Brand Name :HeJin
Model Number :LT-3
Certification :Calibration Certificate(cost additional)
Place of Origin :China
MOQ :1 set
Price :Negotiable
Payment Terms :L/C, T/T
Supply Ability :15 set per month
Delivery Time :30 days
Packaging Details :Plywood
Standard :IEC 60112
Usage :Flame Testing Equipment
Electrode pressure :1.00N±0.05N
Electrodes size :rectangular cross-section of (5 ± 0,1 ) mm × (2 ± 0,1 ) mm
Electrode material :Platinum
Electrode angle :60°
Drops intervals :30 s ± 5 s
Drops height :35 mm ± 5 mm
test voltage :0-600V adjustable
Working volume :> 0.5 M³
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Flammability Testing Equipment IEC 60112 Tracking Index Touch-Screen Operation

Standard:

IEC60112-2009 Method for the determination of the proof and the comparative tracking indices of solid insulating materials.

Application:

It is used for determination of the relative resistance to tracking performance that solid electrical insulating material under the action of an electric field, when the surface exposed to water containing impurities. Flammability Testing Equipment

The test apparatus and test procedure consist of:

1. Two electrodes of platinum with a minimum purity of 99 %.

2. Test circuit with a substantially sinusoidal voltage, variable between 100 V and 600 V at a frequency of 48 Hz to 62 Hz.

3. Test solution A and solution B.

4. Dropping device. Drops of the test solution shall fall on to the specimen surface at intervals of 30 s ± 5 s. The drops shall fall more or less centrally between the electrodes from a height of 35 mm ± 5 mm. Flammability Testing Equipment

Parameter:

Timing device 9999X0.1S Resolution Drip interval Adjustable
Electrode material Platinum The height of the drip 30-40mm
Electrode specifications 5mm*2mm Drip delay 0.2S (solenoid valve open time)
Electrode spacing 4±0.1mm Drip size 45 - 50 drops / cm3
Electrode pressure 1±0.05 N Delay electric circuit 2 ± 0.1S (at 0.5A)
Electrode angle 60° Test voltage range

0-600V

Accuracy:1.5%

Short circuit voltage drop 8% MAX Electrical parameters 1.5KW/220VAC/50Hz
Short-circuit current 1±0.1A Accuracy: 1% Working volume > 0.5 M³

IEC 60112 Flammability Testing Equipment Tracking Index Touch Screen Operation