HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD

Manufacturer from China
Verified Supplier
6 Years
Home / Products / IEC Test Equipment /

IEC 60069-1 IEC Test Equipment Conductor Damage Degree Test Apparatus Rate 10 ± 2 R/Min

Contact Now
HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MsTessa Huang
Contact Now

IEC 60069-1 IEC Test Equipment Conductor Damage Degree Test Apparatus Rate 10 ± 2 R/Min

Ask Latest Price
Video Channel
Brand Name :HeJin
Model Number :HC9933
Certification :Third party calibration certificate/ CE(cost additional)
Place of Origin :China
MOQ :1 Set
Price :Negotiatable
Payment Terms :T/T, L/C
Supply Ability :10 set per month
Delivery Time :30 days
Packaging Details :Plywood
Product name :Conductor Damage Degree Test Apparatus
Control :Manual control, button operation
Test times :0-9999
mass :0.3, 0.4, 0.7, 0.9, 1.4, 2.0kg
Test rate :10 ± 2 r/min
Diameter of Platen :75mm
Diameter of bushing hole :6.5, 9.5, 13, 14.5mm
Test height :260, 280, 300, 320mm
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Conductor Damage Degree Test Apparatus IEC 60069-1 Test Equipment Rate 10 ± 2 r/min

Standard:

IEC 60884-1 ‘Plugs and socket-outlets for household and similar purposes – Part 1: General requirements’ clause 12.2.5, figure 11

IEC 60669-1 ‘Switches for household and similar fixed electrical installations – Part 1: General requirements’ clause 12.2.5, figure 9

Standard description:

Terminals with screw clamping shall be so designed and constructed that they clamp the conductor(s) without undue damage to the conductor(s).

The terminal is placed in the test apparatus according to figure 11 and fitted with rigid, solid, stranded and/or flexible conductor(s), according to table 3 first with the smallest and then with the largest nominal cross-sectional area, the clamping screw(s) or nut(s) being tightened with the torque according to table 6.

Where rigid stranded conductors do not exist, the test may be made with rigid solid conductors only. In this case, there is no need for further tests.

The length of the test conductor shall be 75 mm longer than the height (H) specified in table 9.

The end of the conductor is passed through an appropriate bushing in a plate positioned at a height (H) below the equipment, as given in table 9. The bushing is positioned in a horizontal plane such that its centre line describes a circle of 75 mm diameter, concentric with the centre of the clamping unit in the horizontal plane; the platen is then rotated at a rate of (10 ± 2) r/min.

The distance between the mouth of the clamping unit and the upper surface of the bushing shall be within ±15 mm of the height specified in table 9. The bushing may be lubricated to prevent binding, twisting, or rotation of the insulated conductor.

A mass as specified in table 9 is suspended from the end of the conductor. The duration of the test is approximately 15 min.

During the test, the conductor shall neither slip out of the clamping unit nor break near the clamping unit, nor shall the conductor be damaged in such a way as to render it unfit for further use. IEC Test Equipment

The test shall be repeated with rigid solid conductors where they exist, if the first test has been made with rigid stranded conductors.

Parameter:

Model HC9903
Test rate 10±2 RPM
Diameter of gyration 75mm
Test times 0-9999
Weights 0.3, 0.4, 0.7, 0.9, 1.4, 2.0kg
Test height 260, 280, 300, 320mm
Diameter of bushing hole 6.5, 9.5, 13, 14.5mm
Standards

IEC60884-1, IEC60669-1

IEC Test Equipment

IEC 60069-1 IEC Test Equipment Conductor Damage Degree Test Apparatus Rate 10 ± 2 R/MinIEC 60069-1 IEC Test Equipment Conductor Damage Degree Test Apparatus Rate 10 ± 2 R/Min

Inquiry Cart 0