HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD

Manufacturer from China
Verified Supplier
6 Years
Home / Products / Plug Socket Test Equipment /

Two Stations IEC 60884-1 Plug Socket Test Equipment For Breaking Capacity

Contact Now
HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD
Visit Website
City:guangzhou
Province/State:guangdong
Country/Region:china
Contact Person:MsTessa Huang
Contact Now

Two Stations IEC 60884-1 Plug Socket Test Equipment For Breaking Capacity

Ask Latest Price
Video Channel
Brand Name :HeJin
Model Number :HC9914B/HC9915A
Certification :calibration certificate (cost additional)
Place of Origin :China
MOQ :1 set
Price :Negotiatable
Payment Terms :L/C, T/T
Supply Ability :10 set /month
Delivery Time :30 days
Packaging Details :Plywood
Product name :Switch And Plug-Socket Endurance Tester HC9914B
Control system :PLC control
Working station :2 (customizable)
test time :0-999999, preset
Connecting time :0-99.9s, preset
Standard :IEC 60884-1, IEC60669-1
load box output current :0 ~ 30A
load box output voltage :0-300V
load box power factor :0.3-0.999
load box Capacitance :70uf, 140uf, 73uf optional
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Two Test Stations IEC 60884-1 Plug Socket Test Equipment For Breaking Capacity

Standard:

IEC 60884-1 ‘Plugs and socket-outlets for household and similar purposes – Part 1: General requirements’ clause 20, clause 21 and figure 16;

IEC 60669-1 ‘Switches for household and similar fixed electrical installations – Part 1: General requirements’ clause 18, clause 19.

Application:

It is applicable for the switches breaking capacity and normal operation life test of household and similar fixed electrical installations, also suitable for plugs and sockets’ breaking capacity and normal operation life testing of the household and similar purposes. Plug Socket Test Equipment

Test sample:

The test equipment can do endurance testing for button switch, rocker switch, toggle switch, rotary switch, plug and socket.

Feature:

The test machine is made of aluminum frame, stainless steel seal plate, driven by the servo motor and ball screw, with 7-inch color touch screen, PLC control system, humanized operation interface and powerful digital display. The test times, conduction current time, test speed, test stroke can be preset. It has the electric current display function that can show the sample’s conduction current. The whole test machine has 2 working stations, one station can process linear switches and plugs and sockets, and one station can process rotary switch, the two stations are independent control. When there are continuously switched on or off due to the adhesion or failure, it will alarm and record the appropriate test times, and it alarms when the test times reach the preset value. The test machine will automatically stop when an alarm occurs.

Coupled with the external load bank (resistive, inductive and capacitive) can process loading test, it has a corresponding control system.

Parameter:

SWITCH PLUG SOCKET ENDURANCE TESTER HC9914B
Power AC220V, 50Hz(customizable)
Work station

2 Stations:

1 liner stations: Can test button switch, rocker switch, toggle switch, plug and socket.

1 rotating stations: Can test rotary switch.

work independently

Operation interface 7-inch touch screen
Drive mode Servo motor
Control system PLC control. Plug Socket Test Equipment
Test times 0~999999 times, can be preset
Conduction time 0~999.9s, can be preset
Break time 0~999.9s, can be preset
Test stroke

Linear:0 ~ 100mm, adjustable

Rotate: 0-360., adjustable

Test speed

Linear:10 ~ 200mm/s, adjustable

Rotate: 0-360./s, adjustable

Test environment

Atmospheric pressure 80 ~ 106kpa;

Ambient temperature 5~ 40℃; Relative humidity (20~ 90)%RH; Use place: no violent shaking, no vibration, no electromagnetic interference, no dust, no explosive or corrosive gas, good heat dissipation

LOAD BOX HC9915A
Power Supply AC220,50Hz.
Voltage V Range 0 ~ 300V accuracy ± 0.5% ± 2d
Current A Range 0 ~ 30A accuracy ± 0.5% ± 2d
Power KW Range 0~20KW, accuracy±05%
Power Factor Range 0.3 to 0.999 accuracy ± 0.5% ± 2d
Load Selection Resistive, Inductive and Capacitive load three in one, switchable
Capacitance Selection 70uf, 140uf, 73uf optional
Output Mode Each power, Interval power optional
Count/Preset 0~999999 times, can be preset
Load power capacity 2*10KVA
Output current limit 30A, the load will be automatically cut off when over 32A
Output voltage limit 300V, the load will be automatically cut off when over 320V

Two Stations IEC 60884-1 Plug Socket Test Equipment For Breaking Capacity